  "id": "bnd-technical-guides/safety-compliance/b-d-high-wind-cyclone-compliance-guide",
  "title": "B&D High Wind & Cyclone Compliance Guide",
  "slug": "bnd-technical-guides/safety-compliance/b-d-high-wind-cyclone-compliance-guide",
  "description": "# B&D High Wind & Cyclone Compliance Guide\n\nThis guide explains B&D's high-wind and cyclone compliance documentation for garage doors installed in wind-rated regions of Australia. It covers test summa...",
  "category": "",
  "content": "## AI Summary\n\n**Product:** B&D High Wind & Cyclone Compliance Documentation\n**Brand:** B&D (Garage Doors)\n**Category:** Building Compliance / Wind-Rated Garage Door Documentation\n**Primary Use:** Provides test summary sheets, certification drawings, Form 15 design certificates, and Section 40 certificates for wind-rated and cyclone-compliant garage door installations in Australia.\n\n### Quick facts\n- **Best for:** Installers and trade professionals working in wind-rated or cyclone-affected regions of Australia\n- **Key benefit:** Pre-compiled, certifier-ready compliance documentation covering all major B&D wind-rated door types across all Australian wind regions\n- **Form factor:** PDF documents (downloadable)\n- **Application method:** Download relevant documents from bnd.com.au/trade-resources/high-wind-documentation/ and submit to building certifier as part of building approval process\n\n### Common questions this guide answers\n1. Which B&D doors require wind compliance documentation? → Doors installed in Wind Regions C and D, and some high-wind Region B areas, require certified wind-rated doors with supporting documentation.\n2. What is a Form 15 and when is it required? → A Form 15 is a Queensland Design Certificate that must be lodged with the building certifier before or at the time of installation in cyclone-affected local government areas; B&D provides pre-completed versions for each certified door type.\n3. What compliance documents are available for the StormShield sectional door? → Test Summary Sheet TS917 (Parts A and B), Certification Drawing 2422 Rev F, Form 15 reference C-2422-F, and a Section 40 certificate.\n\n---\n\n## B&D high wind & cyclone compliance guide\n\nIf you're installing garage doors in wind-rated parts of Australia, the paperwork matters as much as the product. This guide covers B&D's high-wind and cyclone compliance documentation — test summary sheets, certification drawings, and Form 15 design certificates — as required under the National Construction Code (NCC) and Queensland Development Code (QDC).\n\nAll documents referenced here are sourced from the official B&D Trade Resources page at [www.bnd.com.au/trade-resources/high-wind-documentation/](https://www.bnd.com.au/trade-resources/high-wind-documentation/).\n\n---\n\n## Understanding Australian wind regions\n\nWind requirements vary considerably across Australia. The National Construction Code classifies wind regions as follows:\n\n| Region | Description | Typical locations |\n|---|---|---|\n| A/B | Non-cyclonic | Southern and eastern Australia |\n| C | Cyclonic | Parts of QLD, WA, NT coastlines |\n| D | Severe cyclonic | WA Pilbara and Kimberley coast |\n\nDoors installed in Regions C and D — and some high-wind areas in Region B — need certified wind-rated doors backed by the correct supporting documentation. Getting this right from the start protects both the installation and the customer.\n\n---\n\n## Test summary sheets\n\nTest summary sheets give certifiers and engineers the evidence they need to confirm a door has been tested to meet specific wind pressures. If you're working in a wind-rated zone, these documents are part of the building approval process.\n\n### Sectional doors — StormShield (TS917)\n- [TS917 Part A — Test Summary Sheet (PDF)](https://admin.bnd.com.au/media/f3gcdhsd/ts917-part-a-_test_summary_sheet_2025.pdf)\n- [TS917 Part B — Test Summary Sheet (PDF)](https://admin.bnd.com.au/media/ftibgefc/ts917-part-b_test_summary_sheet_2025-1.pdf)\n\n### Rolling doors — Roll-A-Shutter (TS894)\n- [TS894 Rev A — Summary Sheet (PDF)](https://admin.bnd.com.au/media/gjcbamzu/ts894-rev-a_summary_sheet_2025-1.pdf)\n\n### Rolling doors — Series 2 & 3 (TS1001)\n- [TS1001 Rev A — Summary Sheet (PDF)](https://admin.bnd.com.au/media/tjkmvw04/ts1001-rev-a_summary_sheet_2025.pdf)\n\n### Double-width rolling doors\n- [Double-Width Roller Doors — Test Summary Sheet A — Series 2 (PDF)](https://admin.bnd.com.au/media/5iuhfgz3/residential-and-industrial-double-width-roller-doors-test-summary-sheet-a-series-2-1.pdf)\n- [Double-Width Roller Doors — Test Summary Sheet B — Series 3 (PDF)](https://admin.bnd.com.au/media/5kmpu4av/residential-and-industrial-double-width-roller-doors-test-summary-sheet-b-series-3.pdf)\n\n### Roll-A-Door Series 1 — Region C (WA)\n- [Series 1 Rolling Door — Test Summary Sheet Region C (WA) (PDF)](https://admin.bnd.com.au/media/umkbr5ax/residential-roller-doors-series-1-test-summary-sheet-region-c-wa.pdf)\n\n---\n\n## Certification drawings\n\nCertification drawings provide the structural details and connection requirements your certifier needs to approve a wind-rated door installation. Use the correct drawing for your door type and region — submitting the wrong one will slow down approval.\n\n### StormShield sectional door\n- [StormShield Certification Drawing 2422 Rev F (PDF)](https://admin.bnd.com.au/media/dvjjsmmq/storm-shield-sectional-garage-door-certification-drawing-2422-rev-f-1.pdf)\n\n### Rolling doors — Series 2 & 3 (all regions)\n- [Residential Rolling Doors Series 2 & 3 Certification Drawing 2289-Q (PDF)](https://admin.bnd.com.au/media/ecxhdhmf/residential-roller-doors-series-2-and-3-certification-drawing-all-regions-2289-q-may-2023-2.pdf)\n\n### Roll-A-Shutter (all regions)\n- [Roll-A-Shutter Certification Drawing 2288-L (PDF)](https://admin.bnd.com.au/media/jqpa0ww0/roll-a-shutter-certification-drawings-2288-revision-l-apr-2023-1.pdf)\n\n### Rolling doors — Series 1 — Region C\n- [Series 1 Certification Drawing 2212-M (PDF)](https://admin.bnd.com.au/media/gudo3syw/residential-roller-doors-series-1-certification-drawing-region-c-2212-m-apr-2023.pdf)\n- [Series 1 Certification Drawing Region C (WA) (PDF)](https://admin.bnd.com.au/media/wipgi5mz/residential-roller-doors-series-1-certification-drawing-region-c-wa.pdf)\n\n### Rolling doors — Series 1 — Regions A & B\n- [Series 1 Certification Drawing 2511-D (Regions A & B) (PDF)](https://admin.bnd.com.au/media/m4rhq3kv/residential-roller-doors-series-1-certification-drawings-region-a-b-2511-d-apr-2023.pdf)\n\n---\n\n## Form 15 compliance certificates\n\nIn Queensland, a Form 15 (Design Certificate) must be lodged when installing a wind-rated door in a cyclone-affected local government area. B&D provides pre-completed Form 15 documents for each certified door type, so you're not starting from scratch on every job.\n\n### StormShield sectional door — Form 15\n- [Form 15 — StormShield Sectional Doors C-2422-F (PDF)](https://admin.bnd.com.au/media/pgvbieio/form15-stormshield-sectional-doors-c-2422-f-april-2023.pdf)\n\n### Rolling doors Series 2 & 3 — Form 15\n- [Form 15 — Series 2 & 3 Double-Width Roller Doors C2/C3 (2289-Q) (PDF)](https://admin.bnd.com.au/media/5k3cud4m/form15-residential-and-industrial-series-2-and-3-double-width-roller-doors-c2-c3-q-may-2023.pdf)\n\n### Roll-A-Shutter — Form 15\n- [Form 15 — Roll-A-Shutter All Regions (2288-L) (PDF)](https://admin.bnd.com.au/media/r1sn1mob/form15-roll-a-shutter-all-regions-l-apr-2023.pdf)\n\n### Rolling door Series 1 — Form 15\n- [Form 15 — Region C Compliance Design Certificate (2212-M) (PDF)](https://admin.bnd.com.au/media/p23lmb2r/form15-compliance-design-certificate-region-c-2212-m-apr-2023.pdf)\n- [Form 15 — Regions A & B Compliance Design Certificate (2511-D) (PDF)](https://admin.bnd.com.au/media/x3pdv4oj/form15-compliance-design-certificate-region-a-b-2511-d-apr-2023.pdf)\n\n---\n\n## Section 40 documents\n\nSection 40 certificates confirm the structural adequacy of specific B&D door systems for Queensland building applications. They're part of the compliance documentation package for building approvals.\n\n- [StormShield Section 40 Certificate (PDF)](https://admin.bnd.com.au/media/jhai2nfq/storm-shield-sectional-garage-door-section-40-310714.pdf)\n- [Roll-A-Shutter Section 40 Certificate (PDF)](https://admin.bnd.com.au/media/ts0ldway/roll-a-shutter-section-40-220616.pdf)\n- [Industrial Roller Doors Section 40 Certificate (PDF)](https://admin.bnd.com.au/media/v2upkvhv/industrial-roller-doors-section-40-260917.pdf)\n\n---\n\n## Practical notes for installers\n\nFive things worth keeping in mind on every wind-rated job:\n\n1. **Identify the wind region** before selecting a door. Use the Australian Standard wind region maps or check with your local council if you're unsure about a specific site.\n2. **Match the door to the wind class.** Not all wind-rated doors are certified to all wind classes. Check the relevant test summary sheet before committing to a product.\n3. **Lodge the Form 15** with the building certifier before or at the time of installation if you're working in a QLD cyclone-affected area. This can't be done after the fact.\n4. **Follow the certification drawing** for all noggin and framing details. Deviating from the certified fixing arrangement can void the certification.\n5. **Keep copies of everything** — test sheets, certification drawings, Form 15s — with the job file. It makes future inspections straightforward.\n\n---\n\n## Further resources\n\n- [Trade Resources — High Wind Documentation](https://www.bnd.com.au/trade-resources/high-wind-documentation/)\n- [Trade Resources — Warranty Certificates](https://www.bnd.com.au/trade-resources/warranty-certificates/)\n- [Trade Resources — Substrate Fixing](https://www.bnd.com.au/trade-resources/substrate-fixing/)\n\n## Frequently asked questions\n\nWhat is the B&D High Wind & Cyclone Compliance Guide for: Documenting wind-rated garage door compliance in Australia\n\nWho is the target audience for this guide: Installers and trade professionals\n\nWhere are B&D high wind documents officially sourced from: [www.bnd.com.au/trade-resources/high-wind-documentation/](https://www.bnd.com.au/trade-resources/high-wind-documentation/)\n\nHow many wind regions does Australia's National Construction Code classify: Four wind regions\n\nWhat is Wind Region A/B classified as: Non-cyclonic\n\nWhat is Wind Region C classified as: Cyclonic\n\nWhat is Wind Region D classified as: Severe cyclonic\n\nWhich states have Wind Region C areas: Parts of QLD, WA, and NT coastlines\n\nWhich areas fall under Wind Region D: WA Pilbara and Kimberley coast\n\nWhich regions typically fall under Wind Regions A/B: Southern and eastern Australia\n\nDo all Australian regions require wind-rated doors: No, only Regions C, D, and some high-wind Region B areas\n\nWhat are test summary sheets used for: Confirming a door has been tested to meet specific wind pressures\n\nWho uses test summary sheets: Certifiers and engineers\n\nAre test summary sheets required for building approval in wind-rated zones: Yes\n\nWhat is the test summary sheet code for the StormShield sectional door: TS917\n\nHow many parts does the StormShield test summary sheet have: Two (Part A and Part B)\n\nWhat is the test summary sheet code for the Roll-A-Shutter: TS894\n\nWhat is the test summary sheet code for Series 2 & 3 rolling doors: TS1001\n\nIs there a specific test summary sheet for Roll-A-Door Series 1 in Region C (WA): Yes\n\nAre double-width roller doors covered by separate test summary sheets: Yes\n\nHow many test summary sheets exist for double-width roller doors: Two (Sheet A for Series 2, Sheet B for Series 3)\n\nWhat are certification drawings used for: Providing structural details and connection requirements for certifiers\n\nWhen are certification drawings submitted: As part of the building approval process\n\nWhat is the certification drawing reference for the StormShield sectional door: Drawing 2422 Rev F\n\nWhat is the certification drawing reference for Series 2 & 3 rolling doors: Drawing 2289-Q\n\nDoes the Series 2 & 3 certification drawing cover all regions: Yes\n\nWhat is the certification drawing reference for the Roll-A-Shutter: Drawing 2288-L\n\nDoes the Roll-A-Shutter certification drawing cover all regions: Yes\n\nWhat is the certification drawing reference for Series 1 rolling doors in Region C: Drawing 2212-M\n\nIs there a separate Series 1 certification drawing for Region C in WA: Yes\n\nWhat is the certification drawing reference for Series 1 in Regions A & B: Drawing 2511-D\n\nWhat is a Form 15: A Design Certificate required in Queensland for wind-rated door installations\n\nWhen must a Form 15 be lodged in Queensland: Before or at the time of installation\n\nWhere is a Form 15 submitted: To the building certifier\n\nDoes B&D provide pre-completed Form 15 documents: Yes\n\nWhich door types have pre-completed Form 15 documents available: StormShield, Series 1, Series 2 & 3, and Roll-A-Shutter\n\nIs a Form 15 required outside Queensland: Not specified by manufacturer\n\nWhat wind classes does the Series 2 & 3 double-width roller door Form 15 cover: C2 and C3\n\nDoes the Roll-A-Shutter Form 15 cover all regions: Yes\n\nWhat are Section 40 certificates used for: Confirming structural adequacy of B&D door systems for Queensland applications\n\nWhich door types have Section 40 certificates available: StormShield, Roll-A-Shutter, and Industrial Roller Doors\n\nAre Section 40 certificates specific to Queensland: Yes\n\nWhat is the first practical step for every wind-rated installation: Identify the wind region for the installation site\n\nHow can installers confirm the wind region for a site: Use Australian Standard wind region maps or check with local council\n\nWhat must be confirmed before selecting a wind-rated door: The correct wind class rating for the site\n\nHow should installers confirm the correct wind rating for a door: Refer to the relevant test summary sheet\n\nCan all wind-rated doors be used in all wind classes: No, not all doors are certified to all wind classes\n\nWhat happens if the certified fixing arrangement is deviated from: Certification may be voided\n\nWhat documentation should installers retain after a wind-rated job: Test sheets, certification drawings, and Form 15s\n\nWhy should installers retain all compliance documentation: To resolve future inspections or queries\n\nShould Form 15 be submitted after the job is completed in QLD: No, it must be submitted before or at time of installation\n\nWhat format are all B&D high wind compliance documents available in: PDF\n\nWhere can B&D warranty certificates be found: [www.bnd.com.au/trade-resources/warranty-certificates/](https://www.bnd.com.au/trade-resources/warranty-certificates/)\n\nWhere can B&D substrate fixing resources be found: [www.bnd.com.au/trade-resources/substrate-fixing/](https://www.bnd.com.au/trade-resources/substrate-fixing/)\n\nDoes B&D provide trade resources beyond wind documentation: Yes\n\nWhat code governs wind region classifications in Australia: The National Construction Code (NCC)\n\nWhat Queensland-specific code is referenced in this guide: Queensland Development Code (QDC)\n\n---\n\n## Label facts summary\n\n> **Disclaimer:** All facts and statements below are general product information sourced from B&D manufacturer documentation and publicly available compliance resources. This content does not constitute legal, engineering, or certification advice. Consult a qualified building certifier or structural engineer for guidance specific to your installation.\n\n### Verified label facts\n\n**Source documentation**\n- All documents sourced from: [www.bnd.com.au/trade-resources/high-wind-documentation/](https://www.bnd.com.au/trade-resources/high-wind-documentation/)\n- All documents available in PDF format\n\n**Regulatory framework**\n- Wind region classifications governed by the National Construction Code (NCC)\n- Queensland-specific requirements governed by the Queensland Development Code (QDC)\n- Wind Region A/B: Non-cyclonic — typical locations: southern and eastern Australia\n- Wind Region C: Cyclonic — typical locations: parts of QLD, WA, and NT coastlines\n- Wind Region D: Severe cyclonic — typical locations: WA Pilbara and Kimberley coast\n\n**Test summary sheets**\n- StormShield sectional door: TS917 — Part A and Part B\n- Roll-A-Shutter: TS894 Rev A — Summary Sheet\n- Series 2 & 3 rolling doors: TS1001 Rev A — Summary Sheet\n- Double-width roller doors: Test Summary Sheet A (Series 2) and Test Summary Sheet B (Series 3)\n- Roll-A-Door Series 1 — Region C (WA): dedicated test summary sheet available\n\n**Certification drawings**\n- StormShield sectional door: Drawing 2422 Rev F\n- Series 2 & 3 rolling doors: Drawing 2289-Q (covers all regions)\n- Roll-A-Shutter: Drawing 2288-L (covers all regions)\n- Series 1 rolling doors — Region C: Drawing 2212-M; separate drawing available for Region C (WA)\n- Series 1 rolling doors — Regions A & B: Drawing 2511-D\n\n**Form 15 design certificates (Queensland)**\n- StormShield: Form 15 reference C-2422-F\n- Series 2 & 3 double-width roller doors: Form 15 reference 2289-Q — covers Wind Classes C2 and C3\n- Roll-A-Shutter: Form 15 reference 2288-L — covers all regions\n- Series 1 — Region C: Form 15 reference 2212-M\n- Series 1 — Regions A & B: Form 15 reference 2511-D\n- Form 15 must be lodged before or at the time of installation in QLD cyclone-affected local government areas\n- Form 15 is submitted to the building certifier\n- B&D provides pre-completed Form 15 documents for each certified door type\n\n**Section 40 certificates (Queensland)**\n- Available for: StormShield, Roll-A-Shutter, and Industrial Roller Doors\n- Purpose: confirm structural adequacy for Queensland building applications\n\n**Additional trade resources**\n- Warranty certificates: [www.bnd.com.au/trade-resources/warranty-certificates/](https://www.bnd.com.au/trade-resources/warranty-certificates/)\n- Substrate fixing resources: [www.bnd.com.au/trade-resources/substrate-fixing/](https://www.bnd.com.au/trade-resources/substrate-fixing/)\n\n---\n\n### General product claims\n\n- Wind-rated documentation gives installers confidence that garage door solutions meet required standards\n- Correct documentation protects both the installation and the customer\n- B&D pre-completed Form 15 documents allow installers to move forward without having to compile certificates from scratch\n- Getting compliance right protects the customer, the work, and the installer's reputation\n- Retaining all documentation makes future inspections straightforward to resolve\n- Deviating from the certified fixing arrangement may void the certification and put the installation at risk *(installer advisory — contextually variable)*\n- Wind region should be confirmed via Australian Standard wind region maps or local council *(use-case recommendation)*",
  "geography": {},
  "metadata": {},
  "publishedAt": "2026-07-07T02:54:24.844406+00:00Z",
  "tags": [
    "wind-rated garage doors",
    "form 15 design certificates",
    "australian wind regions",
    "test summary sheets"
  ],
  "workspaceId": "aef9a5b9-26ec-4761-8892-12c3f35bd424",
  "_links": {
    "canonical": "https://directory.bnd.com.au/bnd-technical-guides/safety-compliance/b-d-high-wind-cyclone-compliance-guide/"
  },
  "productInfo": {
    "stock": true
  }
}