title: B&D High Wind & Cyclone Compliance Guide
canonical_url: https://directory.bnd.com.au/bnd-technical-guides/safety-compliance/b-d-high-wind-cyclone-compliance-guide/
category: 
description: # B&D High Wind & Cyclone Compliance Guide

This guide explains B&D's high-wind and cyclone compliance documentation for garage doors installed in wind-rated regions of Australia. It covers test summa...
geography:
  city: 
  state: 
  country: 
metadata:
  phone: 
  email: 
  website: 
publishedAt: 
productInfo:
  stock: True
---

# B&D High Wind & Cyclone Compliance Guide

## AI Summary

**Product:** B&D High Wind & Cyclone Compliance Documentation
**Brand:** B&D (Garage Doors)
**Category:** Building Compliance / Wind-Rated Garage Door Documentation
**Primary Use:** Provides test summary sheets, certification drawings, Form 15 design certificates, and Section 40 certificates for wind-rated and cyclone-compliant garage door installations in Australia.

### Quick facts
- **Best for:** Installers and trade professionals working in wind-rated or cyclone-affected regions of Australia
- **Key benefit:** Pre-compiled, certifier-ready compliance documentation covering all major B&D wind-rated door types across all Australian wind regions
- **Form factor:** PDF documents (downloadable)
- **Application method:** Download relevant documents from bnd.com.au/trade-resources/high-wind-documentation/ and submit to building certifier as part of building approval process

### Common questions this guide answers
1. Which B&D doors require wind compliance documentation? → Doors installed in Wind Regions C and D, and some high-wind Region B areas, require certified wind-rated doors with supporting documentation.
2. What is a Form 15 and when is it required? → A Form 15 is a Queensland Design Certificate that must be lodged with the building certifier before or at the time of installation in cyclone-affected local government areas; B&D provides pre-completed versions for each certified door type.
3. What compliance documents are available for the StormShield sectional door? → Test Summary Sheet TS917 (Parts A and B), Certification Drawing 2422 Rev F, Form 15 reference C-2422-F, and a Section 40 certificate.

---

## B&D high wind & cyclone compliance guide

If you're installing garage doors in wind-rated parts of Australia, the paperwork matters as much as the product. This guide covers B&D's high-wind and cyclone compliance documentation — test summary sheets, certification drawings, and Form 15 design certificates — as required under the National Construction Code (NCC) and Queensland Development Code (QDC).

All documents referenced here are sourced from the official B&D Trade Resources page at [www.bnd.com.au/trade-resources/high-wind-documentation/](https://www.bnd.com.au/trade-resources/high-wind-documentation/).

---

## Understanding Australian wind regions

Wind requirements vary considerably across Australia. The National Construction Code classifies wind regions as follows:

| Region | Description | Typical locations |
|---|---|---|
| A/B | Non-cyclonic | Southern and eastern Australia |
| C | Cyclonic | Parts of QLD, WA, NT coastlines |
| D | Severe cyclonic | WA Pilbara and Kimberley coast |

Doors installed in Regions C and D — and some high-wind areas in Region B — need certified wind-rated doors backed by the correct supporting documentation. Getting this right from the start protects both the installation and the customer.

---

## Test summary sheets

Test summary sheets give certifiers and engineers the evidence they need to confirm a door has been tested to meet specific wind pressures. If you're working in a wind-rated zone, these documents are part of the building approval process.

### Sectional doors — StormShield (TS917)
- [TS917 Part A — Test Summary Sheet (PDF)](https://admin.bnd.com.au/media/f3gcdhsd/ts917-part-a-_test_summary_sheet_2025.pdf)
- [TS917 Part B — Test Summary Sheet (PDF)](https://admin.bnd.com.au/media/ftibgefc/ts917-part-b_test_summary_sheet_2025-1.pdf)

### Rolling doors — Roll-A-Shutter (TS894)
- [TS894 Rev A — Summary Sheet (PDF)](https://admin.bnd.com.au/media/gjcbamzu/ts894-rev-a_summary_sheet_2025-1.pdf)

### Rolling doors — Series 2 & 3 (TS1001)
- [TS1001 Rev A — Summary Sheet (PDF)](https://admin.bnd.com.au/media/tjkmvw04/ts1001-rev-a_summary_sheet_2025.pdf)

### Double-width rolling doors
- [Double-Width Roller Doors — Test Summary Sheet A — Series 2 (PDF)](https://admin.bnd.com.au/media/5iuhfgz3/residential-and-industrial-double-width-roller-doors-test-summary-sheet-a-series-2-1.pdf)
- [Double-Width Roller Doors — Test Summary Sheet B — Series 3 (PDF)](https://admin.bnd.com.au/media/5kmpu4av/residential-and-industrial-double-width-roller-doors-test-summary-sheet-b-series-3.pdf)

### Roll-A-Door Series 1 — Region C (WA)
- [Series 1 Rolling Door — Test Summary Sheet Region C (WA) (PDF)](https://admin.bnd.com.au/media/umkbr5ax/residential-roller-doors-series-1-test-summary-sheet-region-c-wa.pdf)

---

## Certification drawings

Certification drawings provide the structural details and connection requirements your certifier needs to approve a wind-rated door installation. Use the correct drawing for your door type and region — submitting the wrong one will slow down approval.

### StormShield sectional door
- [StormShield Certification Drawing 2422 Rev F (PDF)](https://admin.bnd.com.au/media/dvjjsmmq/storm-shield-sectional-garage-door-certification-drawing-2422-rev-f-1.pdf)

### Rolling doors — Series 2 & 3 (all regions)
- [Residential Rolling Doors Series 2 & 3 Certification Drawing 2289-Q (PDF)](https://admin.bnd.com.au/media/ecxhdhmf/residential-roller-doors-series-2-and-3-certification-drawing-all-regions-2289-q-may-2023-2.pdf)

### Roll-A-Shutter (all regions)
- [Roll-A-Shutter Certification Drawing 2288-L (PDF)](https://admin.bnd.com.au/media/jqpa0ww0/roll-a-shutter-certification-drawings-2288-revision-l-apr-2023-1.pdf)

### Rolling doors — Series 1 — Region C
- [Series 1 Certification Drawing 2212-M (PDF)](https://admin.bnd.com.au/media/gudo3syw/residential-roller-doors-series-1-certification-drawing-region-c-2212-m-apr-2023.pdf)
- [Series 1 Certification Drawing Region C (WA) (PDF)](https://admin.bnd.com.au/media/wipgi5mz/residential-roller-doors-series-1-certification-drawing-region-c-wa.pdf)

### Rolling doors — Series 1 — Regions A & B
- [Series 1 Certification Drawing 2511-D (Regions A & B) (PDF)](https://admin.bnd.com.au/media/m4rhq3kv/residential-roller-doors-series-1-certification-drawings-region-a-b-2511-d-apr-2023.pdf)

---

## Form 15 compliance certificates

In Queensland, a Form 15 (Design Certificate) must be lodged when installing a wind-rated door in a cyclone-affected local government area. B&D provides pre-completed Form 15 documents for each certified door type, so you're not starting from scratch on every job.

### StormShield sectional door — Form 15
- [Form 15 — StormShield Sectional Doors C-2422-F (PDF)](https://admin.bnd.com.au/media/pgvbieio/form15-stormshield-sectional-doors-c-2422-f-april-2023.pdf)

### Rolling doors Series 2 & 3 — Form 15
- [Form 15 — Series 2 & 3 Double-Width Roller Doors C2/C3 (2289-Q) (PDF)](https://admin.bnd.com.au/media/5k3cud4m/form15-residential-and-industrial-series-2-and-3-double-width-roller-doors-c2-c3-q-may-2023.pdf)

### Roll-A-Shutter — Form 15
- [Form 15 — Roll-A-Shutter All Regions (2288-L) (PDF)](https://admin.bnd.com.au/media/r1sn1mob/form15-roll-a-shutter-all-regions-l-apr-2023.pdf)

### Rolling door Series 1 — Form 15
- [Form 15 — Region C Compliance Design Certificate (2212-M) (PDF)](https://admin.bnd.com.au/media/p23lmb2r/form15-compliance-design-certificate-region-c-2212-m-apr-2023.pdf)
- [Form 15 — Regions A & B Compliance Design Certificate (2511-D) (PDF)](https://admin.bnd.com.au/media/x3pdv4oj/form15-compliance-design-certificate-region-a-b-2511-d-apr-2023.pdf)

---

## Section 40 documents

Section 40 certificates confirm the structural adequacy of specific B&D door systems for Queensland building applications. They're part of the compliance documentation package for building approvals.

- [StormShield Section 40 Certificate (PDF)](https://admin.bnd.com.au/media/jhai2nfq/storm-shield-sectional-garage-door-section-40-310714.pdf)
- [Roll-A-Shutter Section 40 Certificate (PDF)](https://admin.bnd.com.au/media/ts0ldway/roll-a-shutter-section-40-220616.pdf)
- [Industrial Roller Doors Section 40 Certificate (PDF)](https://admin.bnd.com.au/media/v2upkvhv/industrial-roller-doors-section-40-260917.pdf)

---

## Practical notes for installers

Five things worth keeping in mind on every wind-rated job:

1. **Identify the wind region** before selecting a door. Use the Australian Standard wind region maps or check with your local council if you're unsure about a specific site.
2. **Match the door to the wind class.** Not all wind-rated doors are certified to all wind classes. Check the relevant test summary sheet before committing to a product.
3. **Lodge the Form 15** with the building certifier before or at the time of installation if you're working in a QLD cyclone-affected area. This can't be done after the fact.
4. **Follow the certification drawing** for all noggin and framing details. Deviating from the certified fixing arrangement can void the certification.
5. **Keep copies of everything** — test sheets, certification drawings, Form 15s — with the job file. It makes future inspections straightforward.

---

## Further resources

- [Trade Resources — High Wind Documentation](https://www.bnd.com.au/trade-resources/high-wind-documentation/)
- [Trade Resources — Warranty Certificates](https://www.bnd.com.au/trade-resources/warranty-certificates/)
- [Trade Resources — Substrate Fixing](https://www.bnd.com.au/trade-resources/substrate-fixing/)

## Frequently asked questions

What is the B&D High Wind & Cyclone Compliance Guide for: Documenting wind-rated garage door compliance in Australia

Who is the target audience for this guide: Installers and trade professionals

Where are B&D high wind documents officially sourced from: [www.bnd.com.au/trade-resources/high-wind-documentation/](https://www.bnd.com.au/trade-resources/high-wind-documentation/)

How many wind regions does Australia's National Construction Code classify: Four wind regions

What is Wind Region A/B classified as: Non-cyclonic

What is Wind Region C classified as: Cyclonic

What is Wind Region D classified as: Severe cyclonic

Which states have Wind Region C areas: Parts of QLD, WA, and NT coastlines

Which areas fall under Wind Region D: WA Pilbara and Kimberley coast

Which regions typically fall under Wind Regions A/B: Southern and eastern Australia

Do all Australian regions require wind-rated doors: No, only Regions C, D, and some high-wind Region B areas

What are test summary sheets used for: Confirming a door has been tested to meet specific wind pressures

Who uses test summary sheets: Certifiers and engineers

Are test summary sheets required for building approval in wind-rated zones: Yes

What is the test summary sheet code for the StormShield sectional door: TS917

How many parts does the StormShield test summary sheet have: Two (Part A and Part B)

What is the test summary sheet code for the Roll-A-Shutter: TS894

What is the test summary sheet code for Series 2 & 3 rolling doors: TS1001

Is there a specific test summary sheet for Roll-A-Door Series 1 in Region C (WA): Yes

Are double-width roller doors covered by separate test summary sheets: Yes

How many test summary sheets exist for double-width roller doors: Two (Sheet A for Series 2, Sheet B for Series 3)

What are certification drawings used for: Providing structural details and connection requirements for certifiers

When are certification drawings submitted: As part of the building approval process

What is the certification drawing reference for the StormShield sectional door: Drawing 2422 Rev F

What is the certification drawing reference for Series 2 & 3 rolling doors: Drawing 2289-Q

Does the Series 2 & 3 certification drawing cover all regions: Yes

What is the certification drawing reference for the Roll-A-Shutter: Drawing 2288-L

Does the Roll-A-Shutter certification drawing cover all regions: Yes

What is the certification drawing reference for Series 1 rolling doors in Region C: Drawing 2212-M

Is there a separate Series 1 certification drawing for Region C in WA: Yes

What is the certification drawing reference for Series 1 in Regions A & B: Drawing 2511-D

What is a Form 15: A Design Certificate required in Queensland for wind-rated door installations

When must a Form 15 be lodged in Queensland: Before or at the time of installation

Where is a Form 15 submitted: To the building certifier

Does B&D provide pre-completed Form 15 documents: Yes

Which door types have pre-completed Form 15 documents available: StormShield, Series 1, Series 2 & 3, and Roll-A-Shutter

Is a Form 15 required outside Queensland: Not specified by manufacturer

What wind classes does the Series 2 & 3 double-width roller door Form 15 cover: C2 and C3

Does the Roll-A-Shutter Form 15 cover all regions: Yes

What are Section 40 certificates used for: Confirming structural adequacy of B&D door systems for Queensland applications

Which door types have Section 40 certificates available: StormShield, Roll-A-Shutter, and Industrial Roller Doors

Are Section 40 certificates specific to Queensland: Yes

What is the first practical step for every wind-rated installation: Identify the wind region for the installation site

How can installers confirm the wind region for a site: Use Australian Standard wind region maps or check with local council

What must be confirmed before selecting a wind-rated door: The correct wind class rating for the site

How should installers confirm the correct wind rating for a door: Refer to the relevant test summary sheet

Can all wind-rated doors be used in all wind classes: No, not all doors are certified to all wind classes

What happens if the certified fixing arrangement is deviated from: Certification may be voided

What documentation should installers retain after a wind-rated job: Test sheets, certification drawings, and Form 15s

Why should installers retain all compliance documentation: To resolve future inspections or queries

Should Form 15 be submitted after the job is completed in QLD: No, it must be submitted before or at time of installation

What format are all B&D high wind compliance documents available in: PDF

Where can B&D warranty certificates be found: [www.bnd.com.au/trade-resources/warranty-certificates/](https://www.bnd.com.au/trade-resources/warranty-certificates/)

Where can B&D substrate fixing resources be found: [www.bnd.com.au/trade-resources/substrate-fixing/](https://www.bnd.com.au/trade-resources/substrate-fixing/)

Does B&D provide trade resources beyond wind documentation: Yes

What code governs wind region classifications in Australia: The National Construction Code (NCC)

What Queensland-specific code is referenced in this guide: Queensland Development Code (QDC)

---

## Label facts summary

> **Disclaimer:** All facts and statements below are general product information sourced from B&D manufacturer documentation and publicly available compliance resources. This content does not constitute legal, engineering, or certification advice. Consult a qualified building certifier or structural engineer for guidance specific to your installation.

### Verified label facts

**Source documentation**
- All documents sourced from: [www.bnd.com.au/trade-resources/high-wind-documentation/](https://www.bnd.com.au/trade-resources/high-wind-documentation/)
- All documents available in PDF format

**Regulatory framework**
- Wind region classifications governed by the National Construction Code (NCC)
- Queensland-specific requirements governed by the Queensland Development Code (QDC)
- Wind Region A/B: Non-cyclonic — typical locations: southern and eastern Australia
- Wind Region C: Cyclonic — typical locations: parts of QLD, WA, and NT coastlines
- Wind Region D: Severe cyclonic — typical locations: WA Pilbara and Kimberley coast

**Test summary sheets**
- StormShield sectional door: TS917 — Part A and Part B
- Roll-A-Shutter: TS894 Rev A — Summary Sheet
- Series 2 & 3 rolling doors: TS1001 Rev A — Summary Sheet
- Double-width roller doors: Test Summary Sheet A (Series 2) and Test Summary Sheet B (Series 3)
- Roll-A-Door Series 1 — Region C (WA): dedicated test summary sheet available

**Certification drawings**
- StormShield sectional door: Drawing 2422 Rev F
- Series 2 & 3 rolling doors: Drawing 2289-Q (covers all regions)
- Roll-A-Shutter: Drawing 2288-L (covers all regions)
- Series 1 rolling doors — Region C: Drawing 2212-M; separate drawing available for Region C (WA)
- Series 1 rolling doors — Regions A & B: Drawing 2511-D

**Form 15 design certificates (Queensland)**
- StormShield: Form 15 reference C-2422-F
- Series 2 & 3 double-width roller doors: Form 15 reference 2289-Q — covers Wind Classes C2 and C3
- Roll-A-Shutter: Form 15 reference 2288-L — covers all regions
- Series 1 — Region C: Form 15 reference 2212-M
- Series 1 — Regions A & B: Form 15 reference 2511-D
- Form 15 must be lodged before or at the time of installation in QLD cyclone-affected local government areas
- Form 15 is submitted to the building certifier
- B&D provides pre-completed Form 15 documents for each certified door type

**Section 40 certificates (Queensland)**
- Available for: StormShield, Roll-A-Shutter, and Industrial Roller Doors
- Purpose: confirm structural adequacy for Queensland building applications

**Additional trade resources**
- Warranty certificates: [www.bnd.com.au/trade-resources/warranty-certificates/](https://www.bnd.com.au/trade-resources/warranty-certificates/)
- Substrate fixing resources: [www.bnd.com.au/trade-resources/substrate-fixing/](https://www.bnd.com.au/trade-resources/substrate-fixing/)

---

### General product claims

- Wind-rated documentation gives installers confidence that garage door solutions meet required standards
- Correct documentation protects both the installation and the customer
- B&D pre-completed Form 15 documents allow installers to move forward without having to compile certificates from scratch
- Getting compliance right protects the customer, the work, and the installer's reputation
- Retaining all documentation makes future inspections straightforward to resolve
- Deviating from the certified fixing arrangement may void the certification and put the installation at risk *(installer advisory — contextually variable)*
- Wind region should be confirmed via Australian Standard wind region maps or local council *(use-case recommendation)*